Planning condition
environmental health
About this entity
| Fact links | ||
|---|---|---|
| CURIE | planning-condition:U0122147 | no fact link |
| Prefix | planning-condition | Facts |
| Reference | U0122147 | Facts |
| Name | environmental health | Facts |
| Quality | Authoritative: We have some data from the authoritative source | no fact link |
| Dataset | Planning condition | no fact link |
| Organisation | Doncaster Metropolitan Borough Council | no fact link |
| Start date | Facts | |
| End date | Facts | |
| Entry date | 2025-06-21 | Facts |
| Typology | policy | no fact link |
| Notes | Unique Condition | Facts |
| Reason | To ensure that the dwellings are adequately insulated against externally generated noise as required by Policies 44, 54 and 55 of the Local Plan. | Facts |
| Description | The development shall be carried out in accordance with the following measures: 1. All glazing systems to all windows of habitable rooms shall achieve a minimum Rw + Ctr of 29 dB, eg 4/20/4 with argon filled cavity double glazed units. 2. All habitable rooms shall be provided with acoustic trickle vents to meet Building Regulation requirements, which shall achieve a minimum sound reduction, Dn,e,w + Ctr 32 dB,, eg Greenwood MA3051 (alternative whole house mechanical ventilation with heat recovery would also be considered acceptable). 3. A 1.8-metre-high acoustic barrier shall be erected at the northern boundary of the site as shown in orange in Document Boundary Treatments, being solid, imperforate and of surface mass 25kg/sqm. 4. A 1.8-metre high brickwork perimeter wall to the entire north/west boundary of the site, being solid and imperforate and as shown in red in Document (Boundary Treatments). 5. A commissioning report demonstrating compliance with the above conditions shall be submitted for approval to the LPA, prior to first occupation of the respective dwellings, and occupation shall not be permitted until such report is approved. | Facts |
Contents
{
"entry-date": "2025-06-21",
"start-date": "",
"end-date": "",
"entity": 73002847,
"name": "environmental health",
"dataset": "planning-condition",
"typology": "policy",
"reference": "U0122147",
"prefix": "planning-condition",
"organisation-entity": 109,
"geometry": "",
"point": "",
"quality": "authoritative",
"notes": "Unique Condition",
"reason": "To ensure that the dwellings are adequately insulated against externally generated noise as required by Policies 44, 54 and 55 of the Local Plan.",
"description": "The development shall be carried out in accordance with the following measures: 1. All glazing systems to all windows of habitable rooms shall achieve a minimum Rw + Ctr of 29 dB, eg 4/20/4 with argon filled cavity double glazed units. 2. All habitable rooms shall be provided with acoustic trickle vents to meet Building Regulation requirements, which shall achieve a minimum sound reduction, Dn,e,w + Ctr 32 dB,, eg Greenwood MA3051 (alternative whole house mechanical ventilation with heat recovery would also be considered acceptable). 3. A 1.8-metre-high acoustic barrier shall be erected at the northern boundary of the site as shown in orange in Document Boundary Treatments, being solid, imperforate and of surface mass 25kg/sqm. 4. A 1.8-metre high brickwork perimeter wall to the entire north/west boundary of the site, being solid and imperforate and as shown in red in Document (Boundary Treatments). 5. A commissioning report demonstrating compliance with the above conditions shall be submitted for approval to the LPA, prior to first occupation of the respective dwellings, and occupation shall not be permitted until such report is approved."
}
© Crown copyright and database right 2026
Licensed under the Open Government Licence v.3.0.
Help improve this data
Give feedback on this dataset, or email your questions and corrections to digitalland@communities.gov.uk.