Planning condition

Noise

About this entity

Fact links
CURIE planning-condition:U0120732 no fact link
Prefix planning-condition Facts
Reference U0120732 Facts
Name Noise Facts
Quality Authoritative: We have some data from the authoritative source no fact link
Dataset Planning condition no fact link
Organisation Doncaster Metropolitan Borough Council no fact link
Start date Facts
End date Facts
Entry date 2025-06-21 Facts
Typology policy no fact link
Notes Unique Condition Facts
Reason To protect the amenity of future occupiers. Facts
Description The development shall be provided with a Mechanical Ventilation with Heat Recovery (MVHR) system throughout, and no trickle vents shall be fitted to any windows. All studio apartments and bedrooms throughout the development shall be provided with glazing rated at least 45 dB Rw+Ctr and with octave band sound reduction values of at least 32 dB Rw at 63 Hz and 28 dB Rw at 125 Hz. All remaining habitable rooms (living/kitchen spaces) shall be provided with enhanced double glazing rated at least 30 dB Rw+Ctr. Internal noise levels due to mechanical ventilation plant shall not exceed 26 dB(A) in bedrooms and 30 dB(A) in living rooms. A commissioning report demonstrating compliance with the above shall be submitted for approval to the LPA, prior to first occupation of the flats, and occupation shall not be permitted until such report is approved. Facts

Contents

{
        "entry-date": "2025-06-21",
        "start-date": "",
        "end-date": "",
        "entity": 73002642,
        "name": "Noise",
        "dataset": "planning-condition",
        "typology": "policy",
        "reference": "U0120732",
        "prefix": "planning-condition",
        "organisation-entity": "109",
        "geometry": "",
        "point": "",
        "quality": "authoritative",
        "notes": "Unique Condition",
        "reason": "To protect the amenity of future occupiers.",
        "description": "The development shall be provided with a Mechanical Ventilation with Heat Recovery (MVHR) system throughout, and no trickle vents shall be fitted to any windows. All studio apartments and bedrooms throughout the development shall be provided with glazing rated at least 45 dB Rw+Ctr and with octave band sound reduction values of at least 32 dB Rw at 63 Hz and 28 dB Rw at 125 Hz. All remaining habitable rooms (living/kitchen spaces) shall be provided with enhanced double glazing rated at least 30 dB Rw+Ctr. Internal noise levels due to mechanical ventilation plant shall not exceed 26 dB(A) in bedrooms and 30 dB(A) in living rooms. A commissioning report demonstrating compliance with the above shall be submitted for approval to the LPA, prior to first occupation of the flats, and occupation shall not be permitted until such report is approved.",
        "organisation-curie": "local-authority:DNC"
    }