Acoustic Assessment

Provenance

Filters

Field

1 selected
Field
Clear

1 result

Fact Field Value Latest Entry Date
aa54f76c9d7286d11b51af2d5b39079f4010c0dff688edc73417f2f0de4b5a27 description 1) Prior to commencement of the development, the applicant shall submit a report demonstrating the acoustic assessment and specified design criteria required to achieve the following standards, for approval by the local planning authority. All requirements contained within the approved report shall be implemented prior to first occupation of the apartments. A maximum noise level in the following locations of: - Living room/dining area - 35 dB LAeq, 16hr (07.00 - 23.00hrs) due to representative external ambient noise; - Bedroom (daytime resting) - 35 dB LAeq, 16hr (07.00-23.00hrs) due to representative external ambient noise; - Bedroom - 30 dB LAeq, 8hr (23.00 - 07.00hrs) and individual noise events not normally exceeding 45dB max (F time weighting) due to representative external ambient noise; These requirements shall be met with windows closed and alternative means of ventilation provided. 2) Prior to first occupation of the apartments, the applicant shall submit for approval to the local planning authority, a commissioning report demonstrating actual compliance with the above acoustic requirements. The report shall be approved by the local planning authority prior to first occupation of the apartments. 2025-06-21