Planning condition
Noise
About this entity
| Fact links | ||
|---|---|---|
| CURIE | planning-condition:U0120720 | no fact link |
| Prefix | planning-condition | Facts |
| Reference | U0120720 | Facts |
| Name | Noise | Facts |
| Quality | Authoritative: We have some data from the authoritative source | no fact link |
| Dataset | Planning condition | no fact link |
| Organisation | Doncaster Metropolitan Borough Council | no fact link |
| Start date | Facts | |
| End date | Facts | |
| Entry date | 2025-06-21 | Facts |
| Typology | policy | no fact link |
| Notes | Unique Condition | Facts |
| Reason | To protect the amenity of future occupiers. | Facts |
| Description | The development shall be provided with a Mechanical Ventilation with Heat Recovery (MVHR) system throughout, and no trickle vents shall be fitted to any windows. All studio apartments and bedrooms throughout the development shall be provided with glazing rated at least 45 dB Rw+Ctr and with octave band sound reduction values of at least 32 dB Rw at 63 Hz and 28 dB Rw at 125 Hz. All remaining habitable rooms (living/kitchen spaces) shall be provided with enhanced double glazing rated at least 30 dB Rw+Ctr. Internal noise levels due to mechanical ventilation plant shall not exceed 26 dB(A) in bedrooms and 30 dB(A) in living rooms. A commissioning report demonstrating compliance with the above shall be submitted for approval to the LPA, prior to first occupation of the flats, and occupation shall not be permitted until such report is approved. | Facts |
Contents
{
"entry-date": "2025-06-21",
"start-date": "",
"end-date": "",
"entity": 73002631,
"name": "Noise",
"dataset": "planning-condition",
"typology": "policy",
"reference": "U0120720",
"prefix": "planning-condition",
"organisation-entity": "109",
"geometry": "",
"point": "",
"quality": "authoritative",
"notes": "Unique Condition",
"reason": "To protect the amenity of future occupiers.",
"description": "The development shall be provided with a Mechanical Ventilation with Heat Recovery (MVHR) system throughout, and no trickle vents shall be fitted to any windows. All studio apartments and bedrooms throughout the development shall be provided with glazing rated at least 45 dB Rw+Ctr and with octave band sound reduction values of at least 32 dB Rw at 63 Hz and 28 dB Rw at 125 Hz. All remaining habitable rooms (living/kitchen spaces) shall be provided with enhanced double glazing rated at least 30 dB Rw+Ctr. Internal noise levels due to mechanical ventilation plant shall not exceed 26 dB(A) in bedrooms and 30 dB(A) in living rooms. A commissioning report demonstrating compliance with the above shall be submitted for approval to the LPA, prior to first occupation of the flats, and occupation shall not be permitted until such report is approved.",
"organisation-curie": "local-authority:DNC"
}
© Crown copyright and database right 2026
Licensed under the Open Government Licence v.3.0.
Help improve this data
Give feedback on this dataset, or email your questions and corrections to digitalland@communities.gov.uk.