[{"fact":"aa54f76c9d7286d11b51af2d5b39079f4010c0dff688edc73417f2f0de4b5a27","entity":73002789,"reference-entity":"","field":"description","value":"1) Prior to commencement of the development, the applicant shall submit a report demonstrating the acoustic assessment and specified design criteria required to achieve the following standards, for approval by the local planning authority. All requirements contained within the approved report shall be implemented prior to first occupation of the apartments. A maximum noise level in the following locations of: - Living room/dining area - 35 dB LAeq, 16hr (07.00 - 23.00hrs) due to representative external ambient noise; - Bedroom (daytime resting) - 35 dB LAeq, 16hr (07.00-23.00hrs) due to representative external ambient noise; - Bedroom - 30 dB LAeq, 8hr (23.00 - 07.00hrs) and individual noise events not normally exceeding 45dB max (F time weighting) due to representative external ambient noise; These requirements shall be met with windows closed and alternative means of ventilation provided. 2) Prior to first occupation of the apartments, the applicant shall submit for approval to the local planning authority, a commissioning report demonstrating actual compliance with the above acoustic requirements. The report shall be approved by the local planning authority prior to first occupation of the apartments.","entity-name":"Acoustic Assessment","entity-prefix":"planning-condition","entity-reference":"U0121841","earliest-entry-date":"2025-02-25","latest-entry-date":"2025-06-21","latest-resource":"cddbf6b3b9eea723b5249c68a38910c2e0b5179b9d93e006eb17572584b10bdc","resources":""}]